IEEE Std 2778-2020 pdf download – IEEE Guide for Solar Power Plant Grounding for Personal Protection

02-26-2022 comment

IEEE Std 2778-2020 pdf download – IEEE Guide for Solar Power Plant Grounding for Personal Protection
1. Overview 1.1 Scope This guide is primarily concerned with the grounding system design for ground-mount photovoltaic (PV) solar power plants (SPPs) that are utility owned and/or utility scale (5 MW or greater). The focus of the guide is on differences in practices from substation grounding as provided in IEEE Std 80. This guide is not intended for the substations to interconnect the solar plant; however, if the substation is included within the plant, portions of this guide may be applicable. Similarly, this guide does not directly cover small-scale SPPs (such as rooftop type systems), substation grounding, or lightning protection. 1.2 Purpose The intent of this guide is to provide guidance and information pertinent to the grounding practices in SPPs for personnel protection, specifcally to identify differences between substation grounding (covered under IEEE Std 80) and SPPs. This guide is primarily concerned with grounding practices related to personnel protection within SPPs for 50 Hz or 60 Hz systems.
2. Normative references The following referenced documents are indispensable for the application of this document (i.e., they must be understood and used, so each referenced document is cited in text and its relationship to this document is explained). For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments or corrigenda) applies. IEEE Std 80™, IEEE Guide for Safety in AC Substation Grounding. IEEE Std 81™, IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System.
3. Defnitions, acronyms, and abbreviations 3.1 Defnitions For the purposes of this document, the following terms and defnitions apply. The IEEE Standards Dictionary Online should be consulted for terms not defned in this clause. 3 collector system: All cables, underground cables, and/or overhead lines and switchgear from solar inverter and step-up transformer sites to the SPP interconnect substation. The total number of ac collector system circuits is driven by the size of the substation transformer. functionally grounded: A photovoltaic (PV) system that has an electrical reference to ground that is not solidly grounded. personnel protection: Establishment of a grounding system capable of meeting touch and step voltage compliance within the SPP under fault conditions within the context of IEEE Std 80. point of interconnection (POI): The location where the generation facility (SPP) connects to the transmission or distribution systems.

Download infomation Go to download
Note: If you can share this website on your Facebook,Twitter or others,I will share more.

LEAVE A REPLY

Anonymous netizen Fill in information