UL 9540A-2017 pdf download – Test Method for Evaluating Thermal Runaway Fire Propagation in Battery Energy Storage Systems

02-10-2022 comment

UL 9540A-2017 pdf download – Test Method for Evaluating Thermal Runaway Fire Propagation in Battery Energy Storage Systems.
5 General 5.1 Cell 5.1.1 The general cell design shall be documented in the test report, which would include the cell chemistry (cathode, anode and electrolyte materials), the physical format of the cell (i.e. prismatic, cylindrical, pouch), cell electrical rating in capacity and nominal voltage, the overall dimensions of the cell, and its weight. 5.1.2 It shall be documented whether or not the cell complies with UL 1973. 5.2 Module 5.2.1 The overall design of the module shall be documented including the overall dimensions, and the generic enclosure material. The electrical configuration of the cells and the general layout of the module contents shall be documented. 5.2.2 It shall be documented whether or not the module complies with UL 1973. 5.3 Battery energy storage system unit 5.3.1 The overall layout of the BESS including number of modules and electrical configuration of the modules should be documented. The physical layout of the modules, the BMS and other major balance of plant components shall be documented. If the system has an integral fire detection and suppression system, the details of this system shall be noted in the report. 5.3.2 The BESS enclosure overall dimensions and generic material used for the enclosure shall be documented. 5.3.3 The report shall indicate whether or not the BESS complies with UL 9540. PERFORMANCE 6 Cell Level 6.1 Sample 6.1.1 Cells shall be conditioned, prior to testing, through charge and discharge cycles for a minimum of 3 cycles using manufacturer specified methodology. During this process, a relationship between the open circuit voltage and state of charge shall be quantified by measurement. The ambient temperature for this conditioning cycling is to be per 6.2.1, unless the cell needs to be at an elevated ambient in order to be active. If the cell requires an elevated ambient to be active, the conditioning shall be conducted at a temperature necessary per the manufacturer’s specifications.

Download infomation Go to download
Note: If you can share this website on your Facebook,Twitter or others,I will share more.
BS IEC 63085:2021 pdf download – Radiation protection instrumentation – System of spectral identification of liquids in transparent and semitransparent containers (Raman systems) UL Standards free download

BS IEC 63085:2021 pdf download – Radiation protection instrumentation – System of spectral identification of liquids in transparent and semitransparent containers (Raman systems)

BS IEC 63085:2021 pdf download - Radiation protection instrumentation – System of spectral identification of liquids in transparent and semitransparent containers (Raman systems). 3.6 identification result data including the common name of the inspected and identified liquid...
Download Now

LEAVE A REPLY

Anonymous netizen Fill in information