IEEE Std C37.20.1-2015 pdf download – IEEE Standard for Metal-Enclosed Low- Voltage (1 000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear

02-26-2022 comment

IEEE Std C37.20.1-2015 pdf download – IEEE Standard for Metal-Enclosed Low- Voltage (1 000 Vac and below, 3200 Vdc and below) Power Circuit Breaker Switchgear.
production tests: Tests made for quality control by the manufacturer on every device or representative samples, or on parts or materials as required to verify during production that the product meets the design specifications and applicable standards. NOTE—Production tests are sometimes called routine tests. switchgear: A general term covering switching and interrupting devices and their combination with associated control, instruments, metering, protective, and regulating devices; also assemblies of these devices with associated interconnections, accessories, and supporting structures used primarily in connection with the generation, transmission, distribution, and conversion of electric power. switchgear assembly: An assembled equipment (indoor or outdoor) including, but not limited to, one or more of the following categories: switching, interrupting, control, instrumentation, metering, protective, and regulating devices; together with their supporting structures, enclosures, conductors, electrical interconnections, and accessories. Refer to Figure A in the Introduction for types of switchgear assemblies and related standards. through current test: A term used to describe a short-circuit, short-time, or momentary test in which the current flowing through the test specimen is required to be maintained at or above specified levels for a specified duration. tin-surfaced or equivalent: Metallic materials having satisfactory long-term performance that operate within the limits established for tin-surfaced electrical contact parts and conducting mechanical joints. truck-operated cell switch: See: truck-operated contact. truck-operated contact (TOC): A circuit breaker truck-operated auxiliary switch which is mounted in the compartment of a removable circuit breaker and is operated by the circuit breaker frame.
4. Normal (usual) service conditions Standards for the design and performance of LV switchgear are based on usual service conditions as described below. The selection of equipment for a particular application can be based on the construction and ratings as defined in this standard provided that the following usual service conditions exist: a) The temperature of the cooling air (ambient air temperature) surrounding the enclosure of the LV switchgear is within the limits of -30 °C and +40 °C. If ambient temperatures below -5 °C will be experienced while in service, the manufacturer should consider addition of space heating or other means to enable proper circuit breaker operation. If the circuit breaker is suitable for operation correctly in an ambient of -30 °C (instead of the IEEE Std C37.13 minimum ambient of -5 °C), no special measures should be needed. b) The altitude of the installation does not exceed 2000 m above sea level.

Download infomation Go to download
Note: If you can share this website on your Facebook,Twitter or others,I will share more.

LEAVE A REPLY

Anonymous netizen Fill in information